Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Arq. bras. med. vet. zootec. (Online) ; 71(3): 848-856, May-June 2019. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1011316

ABSTRACT

The present study had as an aim to evaluate a right lateral access as an alternative method to laparoscopic ovum pick-up (LOPU) in sheep. Twenty-four Santa Ines ewes were randomly assigned in two groups with twelve animals each: RLD - positioned in right lateral decubitus, with 10º head-down tilt; and DD - positioned in dorsal decubitus with 35º head-down tilt. The following parameters were evaluated every 10 minutes during the procedure: total surgical time (ST), visualized follicles (VF), aspirated follicles (AF), recovered oocytes (RO), mean arterial pressure (MAP), heart rate (HR), respiratory rate (fR) and end tidal CO2 pressure (EtCO2). Pre and postoperative arterial hemogasometry parameters (PaO2, PaCO2, pH, CHCO3 and BE) were also evaluated; and serum fibrinogen levels (SFL) on postoperative period. The values of VF, AF, RO, fR, PaO2, pH, CHCO3, BE and SFL were similar between groups, although ST, HR, MAP, EtCO2 and PaCO2 were higher in LG. Regarding operative periods, PaO2 and pH were lower after surgery (PaO2: 79.1±16.4; 79.2±11.7mmHg; pH: 7.30±0.09; 7.32±0.08) in both groups when compared to preoperative (PaO2: 80.1±14.3; 83.4±10.5 mmHg; pH: 7.38±0.05; 7.39±0.05) while PaCO2 (43.6±4.6; 41.9±5.4mmHg) and CHCO3 (22.8±1.5; 22.7±3.0mmol/L) increased (PaCO2: 54.3±10.9; 46.9±6.3mmHg; CHCO3: 24.8±3.4; 24.4±2.7mmol/L) postoperative. This alternative decubitus presented is a viable procedure and did not differ in oocyte recovery rates in ewes. However, entails cardiorespiratory major alterations compared to conventional procedure, making its practical applicability limited.(AU)


O presente estudo teve como objetivo avaliar o acesso lateral direito como um método alternativo para a recuperação de oócitos por laparoscopia (LOPU) em ovelha. Vinte e quatro ovelhas Santa Inês foram distribuídas aleatoriamente em dois grupos com 12 animais: grupo RLD - posicionado em decúbito lateral direito, cefalodeclive com 10º de inclinação; grupo DD - posicionado em decúbito dorsal em cefalodeclive, inclinação de 35º. Foram avaliados, a cada 10 minutos, durante o procedimento cirúrgico: tempo total da cirurgia (ST), folículos visualizados (VF), folículos aspirados (AF), oócitos recuperados (RO), pressão arterial média (MAP), frequência cardíaca (FC), frequência respiratória (fR) e pressão final de CO2 (EtCO2). Também foram avaliados os parâmetros de hemogasometria arterial pré-operatória e pós-operatória (PaO2, PaCO2, pH, CHCO3 e BE), bem como os níveis séricos de fibrinogênio (SFL) no período pós-operatório. Os valores de VF, AF, RO, fR, PaO2, pH, CHCO3, BE e SFL foram semelhantes entre os grupos, embora ST, FC, MAP, EtCO2 e PaCO2 tenham sido maiores em RLD. Os parâmetros PaO2 e pH foram menores após a cirurgia (PaO2: 79,1±16,4; 79,2±11,7mmHg; pH: 7,30±0,09; 7,32±0,08) em ambos os grupos em relação ao momento pré-cirúrgico (PaO2: 80,1±14,3; 83,4±10,5mmHg; pH: 7,38±0,05; 7,39±0,05), enquanto PaCO2 (43,6±4.6; 41,9±5,4mmHg) e CHCO3 (22,8±1,5; 22,7±3.0mmol/L) aumentaram (PaCO2: 54,3±10,9; 46,9±6,3mmHg; CHCO3: 24,8±3,4; 24,4±2,7mmol/L) após a cirurgia. O decúbito lateral é uma alternativa viável para LOPU e não apresenta diferença para a taxa de recuperação oocitária em ovelhas. No entanto, promove alterações cardiorrespiratórias em comparação com o decúbito dorsal, tornando a sua aplicabilidade prática limitada.(AU)


Subject(s)
Animals , Female , Pregnancy , Sheep, Domestic/surgery , Oocyte Retrieval/methods , Oocyte Retrieval/veterinary , Laparoscopy/methods , Laparoscopy/veterinary
2.
Arq. bras. med. vet. zootec ; 68(4): 858-864, jul.-ago. 2016. ilus
Article in English | LILACS, VETINDEX | ID: lil-792473

ABSTRACT

The aim of this work is study the laparoscopic ovum pick-up (LapOPU) technique in spotted paca, describing surgery details, complications and oocyte recovery rate. Nine healthy adult non-pregnant captive females were used, in a total of 39 procedures. When the surgical plane of anaesthesia was achieved, the females were positioned at 20º Trendelenburg. Three 6mm trocars were placed on right and left inguinal and hypogastric regions. Abdomen was inflated with CO2 and the intra-abdominal pressure was stablished in 10mmHg. Follicular punctures were performed moving the ovaries with atraumatic forceps. For punctures, an 18-gauge 3.5 inch long needle attached to a vacuum system with pressure not exceeding 65mmHg was used. Oocytes were recovered into 50mL centrifuge tubes with media composed of PBS supplemented with 10 IU/mL of heparin and kept at 36°C. R Software was used for statistical analysis. Data normality distribution (Shapiro test) and variances homoscedasticity (Bartlett test) were tested and descriptive statistics (mean±SD) was used to present the results. It was only possible to perform LapOPU in 30 of 39 laparoscopies (76.92%). The surgical total time was 37.34 ± 18.53 minutes. The total number of visualized follicles, aspirated follicles, and retrieved oocytes were 502, 415, and 155, respectively. And the same parameters per animal were: 14.34 ± 12.23, 11.86 ± 10.03, and 4.43 ± 4.69 respectively. Oocyte recovery rate was 32.56 ± 27.32%. In conclusion, caudal positioning of portals with slight triangulation allows good viewing of the abdominal cavity and eases the manipulation of the ovaries. Thus this described LapOPU technique is feasible in spotted paca and easy to perform.(AU)


Objetiva-se, com este trabalho, estudar a técnica de aspiração folicular por videolaparoscopia (LapOPU) em pacas, descrevendo detalhes do procedimento cirúrgico, complicações e taxa de recuperação oocitária. Para isso, foram utilizadas nove fêmeas, saudáveis, adultas, não gestantes e mantidas em cativeiro, totalizando 39 procedimentos. Quandoo plano anestésico cirúrgico foi alcançado, as fêmeas foram posicionadas em Trendelenburg com 20º de angulação. Três trocáteres foram colocados nas regiões inguinais direita e esquerda e hipogástrica. O Abdômen foi insuflado com CO2, e a pressão intra-abdominal foi mantida em 10mmHg. Punções foliculares foram realizadas manipulando-se os ovários com pinças atraumáticas. Para aspirações foliculares, usou-se agulha de 18G com bisel curto acoplado ao sistema de vácuo com pressão não excedendo 65mmHg. Oócitos foram recuperados em tubos de centrifugação de 50mL contendo meio composto de PBS suplementado com 10UI/mL de heparina e mantidos a 36ºC. Usou-se software R para análise estatística. Testaram-se a distribuição normal dos dados (teste de Shapiro) e a homocedasticidade das variâncias (teste de Barlett) e se usaram estatísticas descritivas (média±DP) para apresentar os resultados. Das 39 videolaparoscopias, só foi possível realizar LapOPUem 30 delas (76,92%). O tempo cirúrgico total das LapOPU foi de 37,34 ± 18,53 minutos. Os números totais de folículos visualizados, folículos aspirados e oócitos recuperados foram: 502, 415 e 155, respectivamente. E os mesmos parâmetros por animal foram: 14,34 ± 12,23, 11,86 ± 10,03 e 4,43 ± 4,69, respectivamente. A taxa de recuperação foi de 32,56 ± 27,32%. Assim, conclui-se que o posicionamento caudal de portais, com ligeira triangulação, permite uma boa visualização da cavidade abdominal e facilita a manipulação dos ovários, sendo essa técnica de LapOPU viável em pacas e de fácil execução.(AU)


Subject(s)
Animals , Female , Adult , Cuniculidae , Oocytes , Reproductive Techniques, Assisted/veterinary , Biopsy, Needle/veterinary , Laparoscopy/veterinary
3.
Arq. bras. med. vet. zootec ; 68(1): 243-246, jan.-fev. 2016. ilus
Article in English | LILACS, VETINDEX | ID: biblio-874984

ABSTRACT

O objetivo deste trabalho é descrever o uso do trocater modelo Adapt(tm) no acesso laparoscópico em animais da família dos equídeos. O procedimento cirúrgico foi realizado em 15 equídeos (quatro jumentas, seis cavalos e cinco éguas), com peso médio de 320kg (290kg e 450kg, pesos máximo e mínimo, respectivamente). Os pacientes foram mantidos em posição quadrupedal, sob sedação e bloqueio local. Primeiramente, realizou-se o preparo asséptico, e o acesso foi feito pelo flanco direito ou pelo esquerdo, dependendo da estrutura a ser visualizada. Em todos os procedimentos, foi utilizado o trocater modelo Seal AdaptTM Ports (Teleflex Medical Introduces TautTM, USA), com diâmetro de 12mm. Inicialmente se fez uma incisão de pele de aproximadamente 15mm para inserção da ponta do trocater. Este foi inserido na ferida cirúrgica, realizando-se movimentos de 180º em sentido horário e anti-horário, até atingir a cavidade abdominal. Após esta etapa, o obturador do trocater foi retirado, e a ótica inserida para confirmar o acesso à cavidade abdominal. A síntese das camadas superficiais da muscular foi realizada com fio nylon nº 0, em um padrão Sultan, e posteriormente a dermorrafia, também com nylon nº 0, no padrão de Wolf. O equipamento apresentou eficiência nos procedimentos de dissecação das camadas subcutânea, musculares e peritônio, não ocorrendo significativa hemorragia nessas camadas. Em um paciente muar, ocorreu afastamento do peritônio parietal, e em alguns casos (40%) ocorreu pequeno enfisema subcutâneo no pós-cirúrgico. Todos os pacientes apresentaram boa cicatrização da ferida cirúrgica. O trocater modelo AdaptTM mostrou-se eficiente na abordagem laparoscópica em equinos, apresentando segurança em se estabelecer o acesso e versatilidade no emprego de diversos instrumentais.(AU)


Subject(s)
Animals , Equidae/surgery , Laparoscopy/instrumentation , Video-Assisted Surgery/veterinary , Surgical Instruments/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...